A two-story house has a sizing problem that a single-floor house does not. Water that reaches the upstairs bathroom has climbed past the rest of the plumbing and passes through the same unit you are considering. A unit that looks fine on paper can leave the top floor feeling thin while the kitchen tap still runs strong.
Start with the highest fixture
Find the tap or shower that sits highest above the point where the main line enters the house. Measure its height above the meter or the basement entry and write the number down. Water loses about 1 psi for every 2.3 feet it climbs, so a fixture 20 feet up starts with roughly 9 psi less than the same tap at grade, before any treatment unit is involved. Ask whether that fixture sits on the same branch as the others or on a line the unit feeds directly.
Read the flow rating at the pressure you actually have
Manufacturers and installers quote flow in gallons per minute, often at a stated inlet pressure. Ask the installer which pressure the rating assumes. If your house supply runs lower than that figure, the real flow at the top floor will be lower than the sheet suggests. Ask for the pressure drop across the unit at your target flow, not only the maximum flow it can handle.
Size for the busiest few minutes, not the daily total
In a two-story home, the hardest moment is usually a weekday morning when an upstairs shower, a washer, and a kitchen tap run at once. Ask each company whether its calculation adds fixtures that run together or divides total household use across the day. A sizing based only on daily totals will miss that peak, and the upstairs bath is the first place you will notice it.
Take two pressure readings before you buy
Attach a gauge to an outside hose bib or the basement supply. Record static pressure with nothing running. Then open the top-floor bath and the kitchen tap together and record again. The drop between the two readings shows how much headroom the house has before a unit is added. Give both numbers to every bidder so each proposal is built on the same facts.
Check the top floor at startup
On the day of install, run the upstairs shower on full hot and full cold, then flush a toilet while the washer fills. If the top floor is weak, ask whether the limit is the unit, a bypass or valve setting, or the branch line feeding the upstairs. Get that answer in writing with the readings attached, so the question is settled on paper and not left to memory.
If you want to see how this site evaluates companies before you compare them, read our ranking methodology.